Electrical arcing occurred when a high voltage/high current cross-country power line contacted the boom of a CAT excavator. Current flowed throughout the entire excavator in passing to the ground. In fact, the current that passed through the CAT excavator “crystallized” the ground around the excavator. A view of the subject excavator at the accident scene is shown in Photograph A.

Photograph A High voltage power line contacted the excavator boom.
Metallurgical evaluation of various CAT excavator parts revealed that considerable arcing damage occurred at component part joints and junctions. Photograph B shows engine main bearing arcing damage.

Photograph B Main bearing arcing damage.
Photograph C shows external electrical arcing damage to electrical conduit on the subject excavator.

Photograph C Arcing damage on electrical conduit.
After metallurgical analysis, it was concluded that replacement of individual arc damage parts would be more costly than merely replacing the entire CAT excavator.